Free 24-hour tech support: 724-746-5500
© 2010. All rights reserved. Black Box Corporation.
Rackmount ServSwitch CAT5 KVM Etender Hubs
Heavy-duty
KVM extension
for multiple CPUs.
02/04/2010
#24985
1 of 5
T EC h S PECS
Cable Required —
Between hubs and remote units:
Software: Transparent to software flow control;
ACU1006VRA, ACU1006DVRA, ACUVREM, ACUWREM, ACU1006MRVA:
Flow control: Transparent to hardware and software flow control
(RTS, CTS, DTR, and DSR are all passed through across the link)
Synchronization — H/V or composite, TTL signal levels;
sync polarity is preserved
Category 5 solid unshielded or shielded twisted pair (UTP or
STP), wired to the TIA/EIA-568A or (preferred) -568B standard,
terminated with RJ-45 M connectors
Clamping Voltage — Up to 15 volts
Compatibility —
Video Bandwidth (to -3 dB) —
Video: VGA, SVGA, XGA, XGA-2, or RGsB (sync on green), although if
your system has monitor ID-bit requirements, you might need to
call Black Box for technical support;
ACU1006RA, ACU1012RA, ACU1006DRA, ACU1006SRA,
ACU1006DSRA, ACU1006VRA, ACU1006DVRA: 150 MHz per port;
ACUREM, ACUSREM, ACUVREM, ACUREMSW, ACU1006MRVA:
Intrinsic: 300 MHz;
Across 328 ft. (100 m) UTP: 95 MHz (with equalization)
Video Compensation —
With ACUMREM, ACUWREM, ACU1006MRA: For short- or
long-distance (user-selectable);
With all other remote units: 3-stage continuously variable
Video Coupling — DC
Video I/O Signal Levels — 0.7 volts peak to peak
User Controls —
ACU1006SRA, ACU1006DSRA:
(6) internal data-rate jumpers (1 for each port);
(6) internal flow-control jumper blocks (1 for each port);
ACUREM, ACUSREM, ACUVREM, ACUREMSW:
(2) front-mounted dials: Brightness and Focus;
(3) internal video-distance (cable-length) jumpers;
(1) internal 4-position DIP switch for various options;
ACUSREM:
Keyboard: IBM PC/AT or PS/2 compatible (PC/AT types require connector
adapter);
Mouse: IBM PS/2 compatible two-button, Microsoft® IntelliMouse®,
or Logitech® PS/2 compatible three-button
Compliance — CE Class B; FCC Part 15 Subpart B Class A, IC Class/classe A
Distance (Maximum) —
ACU1006RA, ACU1012RA, ACU1006DRA, ACU1006SRA,
ACU1006DSRA, ACU1006VRA, ACU1006DVRA:
16.4 ft. (5 m) from a local hub to the attached local equipment;
16.4 ft. (5 m) from each remote unit to the attached remote
equipment;
164 ft. (50 m) between a local hub and any Micro remote unit;
1000 ft. (304.8 m) between a local hub and any other
type of remote unit;
ACUREM, ACUSREM, ACUVREM, ACUWREM, ACUREMSW,
ACU1006MRA:
16.4 ft. (5 m) from the remote to the attached remote equipment;
1000 ft. (304.8 m) between a local hub and any other
type of remote unit;
(1) internal data-rate jumper;
(1) internal flow-control jumper block;
ACUMREM, ACU1006MRVA:
16.4 ft. (5 m) between the remote and the attached remote
equipment;
ACUMREM, ACUWREM:
(1) bottom-mounted 2-position DIP switch for video distance (cable
length) and keyboard-command recognition;
ACU1006MRA, ACU1006MRVA:
150 ft. (45.7 m) between a local hub and the micro remote unit
(6) internal 2-position DIP switches for video distance and keyboard-
command recognition, (1) for each local-to-remote link;
ACUVREM, ACUWREM only:
NOTE: With high-quality cables, it might be possible to run farther than
16.4 ft. (5 m) from the hub or a remote unit to attached equipment.
(1) internal microphone-amplification jumper;
ACU1006MRVA only:
(6) internal microphone-amplification jumpers, (1) for each
local-to-remote link
Mean Time Between Failure (MTBF) — 40,000 hours
Interface —
Between local hubs and remote units: Proprietary composite
of all supported types of computer I/O;
On local hubs to CPUs:
Resolution (Maximum) —
ACUREM, ACUSREM, ACUVREM, ACUREMSW:
1600 x 1280: 200 ft. (61 m);
1280 x 1024: 300 ft. (91.4 m);
1024 x 768: 1000 ft. (304.8 m);
ACUMREM, ACUWREM:
1280 x 1024: 150 ft. (45.7 m)
Serial Characteristics —
ACU1006SRA, ACU1006DSRA, ACUSREM:
Data rate: 9600 bps or 9.2 kbps, user selectable;
Data format: 8 data bits, no parity, 1 stop bit (fixed);
ACU1006VRA, ACU1006DVRA, ACUWREM:
Data rate: Up to 19.2 kbps;
Data format: 8 data bits, no parity, 1 stop bit (fixed);
ACUVREM, ACU1006MRVA:
Proprietary composite of VGA-compatible video and IBM
PS/2 compatible keyboard and mouse;
ACU1006SRA, ACU1006DSRA, ACU1006VRA only: TIA/EIA RS-232 (DCE);
ACU1006VRA, ACU1006DVRA only: Bidirectional 3.5-mm mini
stereo audio;
ACU1006DRA, ACU1006DSRA, ACU1006DVRA:
To local monitor: VGA;
To local keyboard and mouse: IBM PS/2 compatible;
Remote units: Depending on the type of unit, either separate
or proprietary composite VGA video and IBM PS/2 compatible
keyboard and mouse;
Data rate: Up to 19.2 kbps;
Data format: 8 data bits, no parity, 1 stop bit;
ACU1006RA, ACU1012RA, ACU1006DRA, ACU1006SRA, ACU1006DSRA,
ACUREM, ACUSREM, ACUMREM, ACUREMSW, ACU1006MRA:
Flow control:
ACUREM, ACUSREM, ACUVREM, ACUREMSW, ACU1006MRVA
only: TIA/EIA RS-232 (DTE);
ACUVREM, ACUWREM, ACU1006MRVA: 3.5-mm mini stereo audio
Hardware: RTS/CTS passed through or looped back, DTR/DSR
passed through or looped back, or none (user-selectable);
02/04/2010
#24985
3 of 5
Connectors —
Indicators — ACU1006RA, ACU1012RA, ACU1006DRA, ACU1006SRA,
ACU1006DSRA, ACU1006VRA, ACU1006DVRA: Front-mounted LEDs
(1 for each port) for power and link integrity;
ACUREM, ACUSREM, ACUMREM, ACUVREM, ACUWREM, ACUREMSW,
ACU1006MRA, ACU1006MRVA: None
All: Power: (1) IEC 320 M to 2.5-mm center-positive barrel connector;
ACU1006RA, ACU1012RA:
Interconnect: (6) or (12) RJ-45;
CPU: (6) or (12) DB25 F;
ACU1006DRA:
Interconnect: (6) RJ-45;
Temperature Tolerance —
Operating: 32 to 104°F (0 to 40°C);
CPU: (6) DB25 F;
Keyboard and mouse: (12) 6-pin mini-DIN F;
Monitor: (6) HD15 F;
Storage: -40 to +176°F (-40 to +80°C)
Humidity Tolerance —
5 to 90% noncondensing
ACU1006SRA:
Interconnect: (6) RJ-45;
Enclosure — Steel
Power —
CPU: (6) DB25 F, (6) DB9 F;
ACU1006DSRA:
Interconnect: (6) RJ-45;
To local hub:
5 VDC at up to 120 mA from each attached CPU’s keyboard and
mouse ports;
CPU: (6) DB25 F, (6) DB9 F;
Keyboard and mouse: (12) 6-pin mini-DIN F;
Monitor: (6) HD15 F;
ACU1006VRA:
Interconnect: (6) RJ-45;
CPU: (6) DB25 F, (6) DB9 F;
Audio I/O: (12) 3.5-mm stereo sockets;
ACU1006DVRA:
Optionally, from desktop power supply, PSU1006E-R2 (certified to
the relevant international safety standards):
Input: 100 to 240 VAC at 47 to 63 Hz from utility-power
(mains) outlet, through detachable power cord and
IEC 320 M inlet, to external transformer;
Output: 5 VDC regulated, at 1.5 amps minimum, from
transformer to local hub;
To remote unit:
Interconnect: (6) RJ-45;
From desktop power supply, PSU1002E-R3 (certified to the
relevant international safety standards):
Input: 100 to 240 VAC at 47 to 63 Hz from utility power outlet,
through detachable power cord and IEC 320 M inlet, to
external transformer;
CPU: (6) DB25 F, (6) DB9 F;
Keyboard and mouse: (12) 6-pin mini-DIN F;
Monitor: (6) HD15 F;
Audio I/O: (12) 3.5-mm stereo sockets;
ACUREM, ACUMREM:
Interconnect: (1) RJ-45;
Keyboard and mouse: (2) 6-pin mini-DIN F;
Monitor: (1) HD15 F;
ACUSREM:
Interconnect: (1) RJ-45;
Keyboard and mouse: (2) 6-pin mini-DIN F;
Monitor: (1) HD15 F;
Output (isolated from mains ground): 9 VDC regulated,
at up to 1 amp, from transformer to remote unit
Size — ACU1006RA, ACU1012RA, ACU1006DRA, ACU1006SRA,
ACU1006DSRA, ACU1006VRA, ACU1006MRA, ACU1006MRVA:
1.75"H x 19"W x 4.5"D (4.4 x 48.3 x 11.4 cm);
ACU1006DVRA: 3.5"H x 17.3"W x 4.5"D (8.9 x 43.9 x 11.4 cm);
ACUREM, ACUSREM, ACUREMSW: 1.4"H x 7"W x 3.9"D
(3.6 x 17.8 x 9.9 cm);
Serial: (1) DB9 F;
ACUVREM, ACUWREM:
Interconnect: (1) RJ-45;
Keyboard and mouse: (2) 6-pin mini-DIN F;
Monitor: (1) HD15 F;
Audio I/O: (2) 3.5-mm stereo sockets;
Serial: (1) DB9 M;
ACUMREM: 1.5"H x 3.1"W x 4.3"D (3.8 x 7.9 x 10.9 cm);
ACUVREM: 1.4"H x 7.8"W x 3.9"D (3.6 x 19.8 x 9.9 cm);
ACUWREM: 2"H x 3.1"W x 4.3"D (5.1 x 7.9 x 10.9 cm)
Weight —
ACU1006RA, ACU1006DRA, ACU1006SRA, ACU1006VRA,
ACU1006DVRA: 3 lb. (1.4 kg);
ACU1012RA: 4.3 lb. (2 kg);
ACUREMSW:
Interconnect: (1) RJ-45;
Keyboard and mouse: (2) 6-pin mini-DIN F;
Monitor: (1) HD15 F;
ACU1006DSRA: 6.6 lb. (3 kg);
ACUREM, ACUSREM, ACUVREM, ACUWREM: 1.1 lb. (0.5 kg);
ACUMREM: 0.5 lb. (0.2 kg);
ACUWREMSW: 1.4 lb. (0.6 kg);
Switch: (1) DB25 F;
ACU1006MRA, ACU1006MRVA: 4 lb. (1.8 kg)0
ACU1006MRA:
Interconnect: (6) RJ-45;
Keyboard and mouse: (12) 6-pin mini-DIN F;
Monitor: (6) HD15 F;
ACU1006MRVA:
Interconnect: (6) RJ-45;
Keyboard and mouse: (12) 6-pin mini-DIN F;
Monitor: (6) HD15 F;
Audio I/O: (12) 3.5-mm stereo sockets;
Serial: (6) DB9 F
02/04/2010
#24985
4 of 5
Item
Code
What’s included
First, choose the hub for your application…
Rackmount ServSwitch Brand CAT5 KVM Extender Hubs
6-Port Standard
When you order a Rackmount ServSwitch Brand CAT5
KVM Extender Hub, you’ll also receive:
✦ (1) 5-VDC (1.5 amps or higher) power-supply transformer
and output cord for optional video power
✦ (1) input cord for the optional power supply, suitable
for your country or region
aCU1006ra
aCU1012ra
aCU1006Dra
aCU1006sra
aCU1006Dsra
12-Port Standard
6-Port Dual-Access
6-Port with Serial
6-Port Dual-Access with Serial
6-Port with Serial and Bidirectional Stereo Audio
aCU1006Vra
6-Port Dual-Access with Serial and Bidirectional Stereo
Audio aCU1006DVra
✦ (1) users’ manual
…then order a remote unit for each active hub port…
Standalone Remote Units
Standard
When you order a Standalone Remote Unit, you’ll also receive:
ACU1006RA:
top: front view;
bottom: rear view
✦
(1) 9-VDC, 1-amp power-supply transformer and output cord
aCUreM
Serial
Micro
aCUsreM
aCUMreM
aCUVreM
aCUWreM
aCUreMsW
✦ (1) power-supply input cord suitable for your country
or region
✦ (1) users’ manual
Serial and Bidirectional Stereo Audio
Micro with Serial and Bidirectional Stereo Audio
with Integrated KVM Switch
When you order a Rackmount Remote Unit, you’ll also receive:
✦ (1) 9-VDC, 1-amp power-supply transformer and output cord
✦ (1) power-supply input cord suitable for your country
or region
✦ (1) pair of rackmount ears for 19" rack
✦ (1) users’ manual
You can also choose rackmount remote units with six units
in a chassis…
Rackmount Remote Units
Micro (ACUMREM)
Micro with Serial and Bidirectional Stereo Audio
(ACUWREM)
aCU1006Mra
aCU1006MrVa
For optimum performance and a 20% savings, order…
Category 5 Solid-Conductor Cable, 4-Pair, Straight-Pinned
Preterminated Patch Cable (Specify Length)
100-MHz Bulk Cable, 1000-ft. (304.8-m)
eYN737Ms
PVC
Spool
Box
eYN840a-1000
eYN840a-B
What else you might need:
Plenum-Rated
• Solid-core 4-pair Category 5 UTP or STP, pinned
and paired according to TIA/EIA-568A or (preferably) TIA/EIA-
568B, to run from your hub to your remote unit. (Bulk CAT5
cable should be terminated with high-quality RJ-45 plugs.)
To use Category 5e or Category 6 cable, call Black Box for
technical support.
• CPU extension cables.
• Serial extension cables.
• A 19" rack or cabinet.
• A monitor for each user station (each monitor must work
when attached directly to any of the CPUs connected
to the extender).
• A standard IBM PC/AT or PS/2 keyboard for each
user station where users will need keyboard control.
• A standard PS/2 compatible mouse for each user station
where users will need mouse control.
Spool
Box
eYN860a-1000
eYN860a-B
Coaxial CPU Cable for CAT5 KVM Extenders
3-ft. (0.9-m)
10-ft. (3-m)
eHN230-0003
eHN230-0010
eHN230-0015
eDN12H-MF
15-ft. (4.6-m)
DB9 Extension Cable, Male/Female
You may also need…
➝
AT®
PS/2® Mouse GHOST Emulator
aC244a
5-Pin DIN Male to 6-Pin Mini-DIN Female Keyboard Adapter
Fa222-r2
19" Rackmount Kit
9-Volt Power Supply
5-Volt Power Supply
If you want to use Cat5e or Cat6 cable, order…
ServSwitch Brand CAT5 Extender Delay Line Module
rMK19U-r2
PsU1002e-r3
PsU1006e-r2
aCUDLY
For better twisted-pair performance, choose…
ServSwitch Wizard™ Skew Compensator
aCU5100a
02/04/2010
#24985
5 of 5
|
Bogen Stereo Amplifier GS 100 User Manual
Bosch Power Tools Grinder CAG180B User Manual
Bowflex Fitness Equipment BD1090 User Manual
Campbell Hausfeld Air Compressor HL5401 Series User Manual
Canon Photo Printer PRO9000 User Manual
Casio Watch 1174 User Manual
Casio Watch 1890 1 User Manual
Chamberlain Battery Charger SL930 User Manual
Chicago Electric Chainsaw Sharpener 91995 User Manual
Chicago Electric Pressure Washer 92146 User Manual